1-2hit |
Takanobu AOYAMA Masafumi KATSUDA Tomohiko KANIE Takashi TAKEO
An equivalent network analysis for an arrangement that combines a microstrip line and coaxial conductor for the purpose of measuring permeability is discussed in this paper. The measurement circuit used consists of a coaxial conductor with a sample housed inside and a short microstrip line connected to both sides. The coaxial conductor is composed of an electrically grounded coaxial metal pipe with open ends and a center conductor. Equivalent networks for this arrangement are investigated to determine the complex permeability from the impedance of the measurement circuit. We have employed a π network composed of a resistor and an inductor connected in series, and shunt capacitors as the equivalent circuit for the measurement portion. It has been found that the measurement error ratio of less than a few percent can be obtained for most frequency ranges of 10 MHz to 500 MHz.
Takanobu AOYAMA Yoshiki SHIBATA Tomohiko KANIE Takashi TAKEO
The authors propose a new method of controlling the isolation of an RF splitter. In the proposed method, a bias current is superimposed on an RF signal to change the permeability of the ferrite core used in the splitter's transformer. By doing this, the splitter isolation can be controlled. Experimental results have shown that superimposing a bias current of 500 mA improves device isolation by about 5 dB without affecting the loss characteristics.