1-3hit |
Weisong LIAO Akira KAINO Tomoaki MASHIKO Sou KUROMASA Masatoshi SAKAI Kazuhiro KUDO
We observed dynamical carrier motion in an OLED device under an external reverse bias application using ExTDR measurement. The rectangular wave pulses were used in our ExTDR to observe the transient impedance of the OLED sample. The falling edge of the transmission waveform reflects the transient impedance after applying pulse voltage during the pulse width. The observed pulse width variation at the falling edge waveform indicates that the frontline of the hole distribution in the hole transport layer was forced to move backward to the ITO electrode.
Mirrored serpentine microstrip lines are proposed for a parallel high speed digital signaling to reduce the peak far-end crosstalk (FEXT) voltage. Mirrored serpentine microstrip lines consist of two serpentine microstrip lines, each one equal to a conventional normal serpentine microstrip line. However, one serpentine microstrip line of the mirrored serpentine microstrip lines is flipped in the length direction, and thus, two serpentine microstrip lines face each other. Time domain reflectometry measurements show that the peak FEXT voltage of the mirrored serpentine microstrip lines is reduced by 56.4% of that of conventional microstrip lines and 30.0% of that of conventional normal serpentine microstrip lines.
Izumi SANKAWA Yahei KOYAMADA Shin-ichi FURUKAWA Tsuneo HORIGUCHI Nobuo TOMITA Yutaka WAKUI
This paper proposes a surveillance system concept, which includes the analysis of fiber fault factors and monitored items, the architecture for diagnosing fiber degradation and the system configuration. Fiber faults are classified into two types. One is fiber failure caused by fiber axial tensile strain and the other is fiber loss increase caused by fiber bending and the absorption of hydrogen molecules. It was found that there is an urgent need for fiber axial strain monitoring, sensitive loss monitoring operating at longer wavelengths and water sensing, in order to detect the origin and early indications of these faults before the service is affected. Moreover, an algorithm for predicting and diagnosing fiber faults based on the detected results was investigated and systematized.