We have developed an estimation system of the electric parameters for liquid materials without a sensor connecting to the testing materials. A PC can be used for the calculation, and the calculation time is about 2 minutes. The accuracy is such that the estimated values are different from the nominal values by less than 2%.
The copyright of the original papers published on this site belongs to IEICE. Unauthorized use of the original or translated papers is prohibited. See IEICE Provisions on Copyright for details.
Copy
Toshihide TOSAKA, Isamu NAGANO, Satoshi YAGITANI, "Development of an Estimation System for the Relative Dielectric Constant of Liquid Materials" in IEICE TRANSACTIONS on Communications,
vol. E88-B, no. 4, pp. 1746-1747, April 2005, doi: 10.1093/ietcom/e88-b.4.1746.
Abstract: We have developed an estimation system of the electric parameters for liquid materials without a sensor connecting to the testing materials. A PC can be used for the calculation, and the calculation time is about 2 minutes. The accuracy is such that the estimated values are different from the nominal values by less than 2%.
URL: https://globals.ieice.org/en_transactions/communications/10.1093/ietcom/e88-b.4.1746/_p
Copy
@ARTICLE{e88-b_4_1746,
author={Toshihide TOSAKA, Isamu NAGANO, Satoshi YAGITANI, },
journal={IEICE TRANSACTIONS on Communications},
title={Development of an Estimation System for the Relative Dielectric Constant of Liquid Materials},
year={2005},
volume={E88-B},
number={4},
pages={1746-1747},
abstract={We have developed an estimation system of the electric parameters for liquid materials without a sensor connecting to the testing materials. A PC can be used for the calculation, and the calculation time is about 2 minutes. The accuracy is such that the estimated values are different from the nominal values by less than 2%.},
keywords={},
doi={10.1093/ietcom/e88-b.4.1746},
ISSN={},
month={April},}
Copy
TY - JOUR
TI - Development of an Estimation System for the Relative Dielectric Constant of Liquid Materials
T2 - IEICE TRANSACTIONS on Communications
SP - 1746
EP - 1747
AU - Toshihide TOSAKA
AU - Isamu NAGANO
AU - Satoshi YAGITANI
PY - 2005
DO - 10.1093/ietcom/e88-b.4.1746
JO - IEICE TRANSACTIONS on Communications
SN -
VL - E88-B
IS - 4
JA - IEICE TRANSACTIONS on Communications
Y1 - April 2005
AB - We have developed an estimation system of the electric parameters for liquid materials without a sensor connecting to the testing materials. A PC can be used for the calculation, and the calculation time is about 2 minutes. The accuracy is such that the estimated values are different from the nominal values by less than 2%.
ER -