Since the development of odor sensing system is required in many fields, we have been developing the system using QCM (Quartz Crystal Microbalance, 10 MHz AT-cut) array and neural-network pattern recognition. Since it is important to obtain stable sensor responses, a sensing film of lipid blended with PVC (polyvinyl chloride) was studied here. First, we studied the stability of various sensing films e. g. , phospholipids, GC liquid stationary phase materials and others in odor sensing system. It was found that most of lipids were stable, while PEG 200, octadecane and DBP were not stable materials. Second, we studied to obtain a stable QCM sensor using a sensing film blended with PVC. 4 plasticizers blended with PVC were systematically characterized, analyzing the pattern of QCM sensor responses by multivariate analysis. It was found that the pattern of DOPP was very different from that of PVC. Thus, we adopted DOPP as plasticizer and the stable sensor response was obtained using a lipid film blended with both PVC and DOPP. Finally, we studied the influence of sensing film materials on the stability of QCM sensors. It was found that the loss of sensing film mass after many vapor exposures depended upon the molecular weight.
The copyright of the original papers published on this site belongs to IEICE. Unauthorized use of the original or translated papers is prohibited. See IEICE Provisions on Copyright for details.
Copy
Junichi IDE, Yukihiko NAKAMURA, Takamichi NAKAMOTO, Toyosaka MORIIZUMI, "Study of Stability of Sensing Film in Odor Sensing System" in IEICE TRANSACTIONS on Electronics,
vol. E81-C, no. 7, pp. 1057-1063, July 1998, doi: .
Abstract: Since the development of odor sensing system is required in many fields, we have been developing the system using QCM (Quartz Crystal Microbalance, 10 MHz AT-cut) array and neural-network pattern recognition. Since it is important to obtain stable sensor responses, a sensing film of lipid blended with PVC (polyvinyl chloride) was studied here. First, we studied the stability of various sensing films e. g. , phospholipids, GC liquid stationary phase materials and others in odor sensing system. It was found that most of lipids were stable, while PEG 200, octadecane and DBP were not stable materials. Second, we studied to obtain a stable QCM sensor using a sensing film blended with PVC. 4 plasticizers blended with PVC were systematically characterized, analyzing the pattern of QCM sensor responses by multivariate analysis. It was found that the pattern of DOPP was very different from that of PVC. Thus, we adopted DOPP as plasticizer and the stable sensor response was obtained using a lipid film blended with both PVC and DOPP. Finally, we studied the influence of sensing film materials on the stability of QCM sensors. It was found that the loss of sensing film mass after many vapor exposures depended upon the molecular weight.
URL: https://globals.ieice.org/en_transactions/electronics/10.1587/e81-c_7_1057/_p
Copy
@ARTICLE{e81-c_7_1057,
author={Junichi IDE, Yukihiko NAKAMURA, Takamichi NAKAMOTO, Toyosaka MORIIZUMI, },
journal={IEICE TRANSACTIONS on Electronics},
title={Study of Stability of Sensing Film in Odor Sensing System},
year={1998},
volume={E81-C},
number={7},
pages={1057-1063},
abstract={Since the development of odor sensing system is required in many fields, we have been developing the system using QCM (Quartz Crystal Microbalance, 10 MHz AT-cut) array and neural-network pattern recognition. Since it is important to obtain stable sensor responses, a sensing film of lipid blended with PVC (polyvinyl chloride) was studied here. First, we studied the stability of various sensing films e. g. , phospholipids, GC liquid stationary phase materials and others in odor sensing system. It was found that most of lipids were stable, while PEG 200, octadecane and DBP were not stable materials. Second, we studied to obtain a stable QCM sensor using a sensing film blended with PVC. 4 plasticizers blended with PVC were systematically characterized, analyzing the pattern of QCM sensor responses by multivariate analysis. It was found that the pattern of DOPP was very different from that of PVC. Thus, we adopted DOPP as plasticizer and the stable sensor response was obtained using a lipid film blended with both PVC and DOPP. Finally, we studied the influence of sensing film materials on the stability of QCM sensors. It was found that the loss of sensing film mass after many vapor exposures depended upon the molecular weight.},
keywords={},
doi={},
ISSN={},
month={July},}
Copy
TY - JOUR
TI - Study of Stability of Sensing Film in Odor Sensing System
T2 - IEICE TRANSACTIONS on Electronics
SP - 1057
EP - 1063
AU - Junichi IDE
AU - Yukihiko NAKAMURA
AU - Takamichi NAKAMOTO
AU - Toyosaka MORIIZUMI
PY - 1998
DO -
JO - IEICE TRANSACTIONS on Electronics
SN -
VL - E81-C
IS - 7
JA - IEICE TRANSACTIONS on Electronics
Y1 - July 1998
AB - Since the development of odor sensing system is required in many fields, we have been developing the system using QCM (Quartz Crystal Microbalance, 10 MHz AT-cut) array and neural-network pattern recognition. Since it is important to obtain stable sensor responses, a sensing film of lipid blended with PVC (polyvinyl chloride) was studied here. First, we studied the stability of various sensing films e. g. , phospholipids, GC liquid stationary phase materials and others in odor sensing system. It was found that most of lipids were stable, while PEG 200, octadecane and DBP were not stable materials. Second, we studied to obtain a stable QCM sensor using a sensing film blended with PVC. 4 plasticizers blended with PVC were systematically characterized, analyzing the pattern of QCM sensor responses by multivariate analysis. It was found that the pattern of DOPP was very different from that of PVC. Thus, we adopted DOPP as plasticizer and the stable sensor response was obtained using a lipid film blended with both PVC and DOPP. Finally, we studied the influence of sensing film materials on the stability of QCM sensors. It was found that the loss of sensing film mass after many vapor exposures depended upon the molecular weight.
ER -