A novel method for measuring microwave reflection coefficients without the open and load standards is proposed. In this method, a single probe is inserted into an air line and the output wave is detected by a vector detector. Offset shorts are used for the calibration. The measurement system is constructed using 7 mm coaxial line and APC7 connectors. The result of the measurement in the frequency range 1-9 GHz shows the possibility of the proposed method. All the major systematic errors can be estimated from the data that is easily obtainable.
The copyright of the original papers published on this site belongs to IEICE. Unauthorized use of the original or translated papers is prohibited. See IEICE Provisions on Copyright for details.
Copy
Takashi IWASAKI, Makoto TAKASHIMA, "Single Probe Method with Vector Detection for Measuring Microwave Reflection Coefficient" in IEICE TRANSACTIONS on Electronics,
vol. E87-C, no. 5, pp. 665-671, May 2004, doi: .
Abstract: A novel method for measuring microwave reflection coefficients without the open and load standards is proposed. In this method, a single probe is inserted into an air line and the output wave is detected by a vector detector. Offset shorts are used for the calibration. The measurement system is constructed using 7 mm coaxial line and APC7 connectors. The result of the measurement in the frequency range 1-9 GHz shows the possibility of the proposed method. All the major systematic errors can be estimated from the data that is easily obtainable.
URL: https://globals.ieice.org/en_transactions/electronics/10.1587/e87-c_5_665/_p
Copy
@ARTICLE{e87-c_5_665,
author={Takashi IWASAKI, Makoto TAKASHIMA, },
journal={IEICE TRANSACTIONS on Electronics},
title={Single Probe Method with Vector Detection for Measuring Microwave Reflection Coefficient},
year={2004},
volume={E87-C},
number={5},
pages={665-671},
abstract={A novel method for measuring microwave reflection coefficients without the open and load standards is proposed. In this method, a single probe is inserted into an air line and the output wave is detected by a vector detector. Offset shorts are used for the calibration. The measurement system is constructed using 7 mm coaxial line and APC7 connectors. The result of the measurement in the frequency range 1-9 GHz shows the possibility of the proposed method. All the major systematic errors can be estimated from the data that is easily obtainable.},
keywords={},
doi={},
ISSN={},
month={May},}
Copy
TY - JOUR
TI - Single Probe Method with Vector Detection for Measuring Microwave Reflection Coefficient
T2 - IEICE TRANSACTIONS on Electronics
SP - 665
EP - 671
AU - Takashi IWASAKI
AU - Makoto TAKASHIMA
PY - 2004
DO -
JO - IEICE TRANSACTIONS on Electronics
SN -
VL - E87-C
IS - 5
JA - IEICE TRANSACTIONS on Electronics
Y1 - May 2004
AB - A novel method for measuring microwave reflection coefficients without the open and load standards is proposed. In this method, a single probe is inserted into an air line and the output wave is detected by a vector detector. Offset shorts are used for the calibration. The measurement system is constructed using 7 mm coaxial line and APC7 connectors. The result of the measurement in the frequency range 1-9 GHz shows the possibility of the proposed method. All the major systematic errors can be estimated from the data that is easily obtainable.
ER -