High-power protection switch utilizing a new stub/line selectable configuration is presented. By employing the proposed circuit topology, the insertion loss at receiving mode and the power handling capability at transmitting mode can be independently designed. Therefore, the proposed circuit is able to achieve low insertion loss at receiving mode while keeping high-power performance at transmitting mode. To verify this methodology, MMIC switch has been fabricated in Ka-band. The circuit has achieved the insertion loss of 2 dB, the isolation of 25 dB, and the power handling capability of 40 dBm at 5% bandwidth.
The copyright of the original papers published on this site belongs to IEICE. Unauthorized use of the original or translated papers is prohibited. See IEICE Provisions on Copyright for details.
Copy
Masatake HANGAI, Kazuhiko NAKAHARA, Mamiko YAMAGUCHI, Morishige HIEDA, "High-Power Protection Switch Using Stub/Line Selectable Circuits" in IEICE TRANSACTIONS on Electronics,
vol. E94-C, no. 5, pp. 814-819, May 2011, doi: 10.1587/transele.E94.C.814.
Abstract: High-power protection switch utilizing a new stub/line selectable configuration is presented. By employing the proposed circuit topology, the insertion loss at receiving mode and the power handling capability at transmitting mode can be independently designed. Therefore, the proposed circuit is able to achieve low insertion loss at receiving mode while keeping high-power performance at transmitting mode. To verify this methodology, MMIC switch has been fabricated in Ka-band. The circuit has achieved the insertion loss of 2 dB, the isolation of 25 dB, and the power handling capability of 40 dBm at 5% bandwidth.
URL: https://globals.ieice.org/en_transactions/electronics/10.1587/transele.E94.C.814/_p
Copy
@ARTICLE{e94-c_5_814,
author={Masatake HANGAI, Kazuhiko NAKAHARA, Mamiko YAMAGUCHI, Morishige HIEDA, },
journal={IEICE TRANSACTIONS on Electronics},
title={High-Power Protection Switch Using Stub/Line Selectable Circuits},
year={2011},
volume={E94-C},
number={5},
pages={814-819},
abstract={High-power protection switch utilizing a new stub/line selectable configuration is presented. By employing the proposed circuit topology, the insertion loss at receiving mode and the power handling capability at transmitting mode can be independently designed. Therefore, the proposed circuit is able to achieve low insertion loss at receiving mode while keeping high-power performance at transmitting mode. To verify this methodology, MMIC switch has been fabricated in Ka-band. The circuit has achieved the insertion loss of 2 dB, the isolation of 25 dB, and the power handling capability of 40 dBm at 5% bandwidth.},
keywords={},
doi={10.1587/transele.E94.C.814},
ISSN={1745-1353},
month={May},}
Copy
TY - JOUR
TI - High-Power Protection Switch Using Stub/Line Selectable Circuits
T2 - IEICE TRANSACTIONS on Electronics
SP - 814
EP - 819
AU - Masatake HANGAI
AU - Kazuhiko NAKAHARA
AU - Mamiko YAMAGUCHI
AU - Morishige HIEDA
PY - 2011
DO - 10.1587/transele.E94.C.814
JO - IEICE TRANSACTIONS on Electronics
SN - 1745-1353
VL - E94-C
IS - 5
JA - IEICE TRANSACTIONS on Electronics
Y1 - May 2011
AB - High-power protection switch utilizing a new stub/line selectable configuration is presented. By employing the proposed circuit topology, the insertion loss at receiving mode and the power handling capability at transmitting mode can be independently designed. Therefore, the proposed circuit is able to achieve low insertion loss at receiving mode while keeping high-power performance at transmitting mode. To verify this methodology, MMIC switch has been fabricated in Ka-band. The circuit has achieved the insertion loss of 2 dB, the isolation of 25 dB, and the power handling capability of 40 dBm at 5% bandwidth.
ER -