Two types of low-coherence millimeter-wave sources for photonic millimeter-wave ellipsometry are compared. A broadband signal (125-GHz bandwidth) or a narrowband one (0.5-GHz bandwidth) is used to measure the complex relative dielectric constants of purified water, and the narrowband signal is revealed to be suitable for accurate measurement.
Hiroshi YAMAMOTO
Kitasato University
Hiroshi ITO
Kitasato University
The copyright of the original papers published on this site belongs to IEICE. Unauthorized use of the original or translated papers is prohibited. See IEICE Provisions on Copyright for details.
Copy
Hiroshi YAMAMOTO, Hiroshi ITO, "Millimeter-Wave Ellipsometry Using Low-Coherence Light Source" in IEICE TRANSACTIONS on Electronics,
vol. E97-C, no. 5, pp. 460-462, May 2014, doi: 10.1587/transele.E97.C.460.
Abstract: Two types of low-coherence millimeter-wave sources for photonic millimeter-wave ellipsometry are compared. A broadband signal (125-GHz bandwidth) or a narrowband one (0.5-GHz bandwidth) is used to measure the complex relative dielectric constants of purified water, and the narrowband signal is revealed to be suitable for accurate measurement.
URL: https://globals.ieice.org/en_transactions/electronics/10.1587/transele.E97.C.460/_p
Copy
@ARTICLE{e97-c_5_460,
author={Hiroshi YAMAMOTO, Hiroshi ITO, },
journal={IEICE TRANSACTIONS on Electronics},
title={Millimeter-Wave Ellipsometry Using Low-Coherence Light Source},
year={2014},
volume={E97-C},
number={5},
pages={460-462},
abstract={Two types of low-coherence millimeter-wave sources for photonic millimeter-wave ellipsometry are compared. A broadband signal (125-GHz bandwidth) or a narrowband one (0.5-GHz bandwidth) is used to measure the complex relative dielectric constants of purified water, and the narrowband signal is revealed to be suitable for accurate measurement.},
keywords={},
doi={10.1587/transele.E97.C.460},
ISSN={1745-1353},
month={May},}
Copy
TY - JOUR
TI - Millimeter-Wave Ellipsometry Using Low-Coherence Light Source
T2 - IEICE TRANSACTIONS on Electronics
SP - 460
EP - 462
AU - Hiroshi YAMAMOTO
AU - Hiroshi ITO
PY - 2014
DO - 10.1587/transele.E97.C.460
JO - IEICE TRANSACTIONS on Electronics
SN - 1745-1353
VL - E97-C
IS - 5
JA - IEICE TRANSACTIONS on Electronics
Y1 - May 2014
AB - Two types of low-coherence millimeter-wave sources for photonic millimeter-wave ellipsometry are compared. A broadband signal (125-GHz bandwidth) or a narrowband one (0.5-GHz bandwidth) is used to measure the complex relative dielectric constants of purified water, and the narrowband signal is revealed to be suitable for accurate measurement.
ER -