A quartz-crystal-microbalance (QCM) and surface-plasmon-resonance (SPR) hybrid sensor was prepared, and the depositions of polymer electrolytes layer-by-layer (LbL) films were observed in situ. The estimated thicknesses obtained from the QCM method were different from those obtained from the SPR method. This was estimated to be caused by film swelling and water contained in the film.
Keisuke KAWACHI
Niigata University
Kazunari SHINBO
Niigata University
Yasuo OHDAIRA
Niigata University
Akira BABA
Niigata University
Keizo KATO
Niigata University
Futao KANEKO
Niigata University
The copyright of the original papers published on this site belongs to IEICE. Unauthorized use of the original or translated papers is prohibited. See IEICE Provisions on Copyright for details.
Copy
Keisuke KAWACHI, Kazunari SHINBO, Yasuo OHDAIRA, Akira BABA, Keizo KATO, Futao KANEKO, "Evaluation of a PAH/PSS Layer-by-Layer Deposited Film Using a Quartz-Crystal-Microbalance and Surface-Plasmon-Resonance Hybrid Sensor" in IEICE TRANSACTIONS on Electronics,
vol. E98-C, no. 2, pp. 136-138, February 2015, doi: 10.1587/transele.E98.C.136.
Abstract: A quartz-crystal-microbalance (QCM) and surface-plasmon-resonance (SPR) hybrid sensor was prepared, and the depositions of polymer electrolytes layer-by-layer (LbL) films were observed in situ. The estimated thicknesses obtained from the QCM method were different from those obtained from the SPR method. This was estimated to be caused by film swelling and water contained in the film.
URL: https://globals.ieice.org/en_transactions/electronics/10.1587/transele.E98.C.136/_p
Copy
@ARTICLE{e98-c_2_136,
author={Keisuke KAWACHI, Kazunari SHINBO, Yasuo OHDAIRA, Akira BABA, Keizo KATO, Futao KANEKO, },
journal={IEICE TRANSACTIONS on Electronics},
title={Evaluation of a PAH/PSS Layer-by-Layer Deposited Film Using a Quartz-Crystal-Microbalance and Surface-Plasmon-Resonance Hybrid Sensor},
year={2015},
volume={E98-C},
number={2},
pages={136-138},
abstract={A quartz-crystal-microbalance (QCM) and surface-plasmon-resonance (SPR) hybrid sensor was prepared, and the depositions of polymer electrolytes layer-by-layer (LbL) films were observed in situ. The estimated thicknesses obtained from the QCM method were different from those obtained from the SPR method. This was estimated to be caused by film swelling and water contained in the film.},
keywords={},
doi={10.1587/transele.E98.C.136},
ISSN={1745-1353},
month={February},}
Copy
TY - JOUR
TI - Evaluation of a PAH/PSS Layer-by-Layer Deposited Film Using a Quartz-Crystal-Microbalance and Surface-Plasmon-Resonance Hybrid Sensor
T2 - IEICE TRANSACTIONS on Electronics
SP - 136
EP - 138
AU - Keisuke KAWACHI
AU - Kazunari SHINBO
AU - Yasuo OHDAIRA
AU - Akira BABA
AU - Keizo KATO
AU - Futao KANEKO
PY - 2015
DO - 10.1587/transele.E98.C.136
JO - IEICE TRANSACTIONS on Electronics
SN - 1745-1353
VL - E98-C
IS - 2
JA - IEICE TRANSACTIONS on Electronics
Y1 - February 2015
AB - A quartz-crystal-microbalance (QCM) and surface-plasmon-resonance (SPR) hybrid sensor was prepared, and the depositions of polymer electrolytes layer-by-layer (LbL) films were observed in situ. The estimated thicknesses obtained from the QCM method were different from those obtained from the SPR method. This was estimated to be caused by film swelling and water contained in the film.
ER -