The accumulated metallic phase arc duration in Ag electrical contacts was log-proportional to the amount of electrode mass change, and the relationship was irrespective of the air pressure condition. It can be considered that the electrode mass change closely depends on the metallic phase arc.
The copyright of the original papers published on this site belongs to IEICE. Unauthorized use of the original or translated papers is prohibited. See IEICE Provisions on Copyright for details.
Copy
Hideaki SONE, Masao NAKAI, Tasuku TAKAGI, "A Measurement on the Relationship between Metallic Phase Arc Duration and Electrode Mass Change in Ag Contacts" in IEICE TRANSACTIONS on transactions,
vol. E71-E, no. 4, pp. 268-271, April 1988, doi: .
Abstract: The accumulated metallic phase arc duration in Ag electrical contacts was log-proportional to the amount of electrode mass change, and the relationship was irrespective of the air pressure condition. It can be considered that the electrode mass change closely depends on the metallic phase arc.
URL: https://globals.ieice.org/en_transactions/transactions/10.1587/e71-e_4_268/_p
Copy
@ARTICLE{e71-e_4_268,
author={Hideaki SONE, Masao NAKAI, Tasuku TAKAGI, },
journal={IEICE TRANSACTIONS on transactions},
title={A Measurement on the Relationship between Metallic Phase Arc Duration and Electrode Mass Change in Ag Contacts},
year={1988},
volume={E71-E},
number={4},
pages={268-271},
abstract={The accumulated metallic phase arc duration in Ag electrical contacts was log-proportional to the amount of electrode mass change, and the relationship was irrespective of the air pressure condition. It can be considered that the electrode mass change closely depends on the metallic phase arc.},
keywords={},
doi={},
ISSN={},
month={April},}
Copy
TY - JOUR
TI - A Measurement on the Relationship between Metallic Phase Arc Duration and Electrode Mass Change in Ag Contacts
T2 - IEICE TRANSACTIONS on transactions
SP - 268
EP - 271
AU - Hideaki SONE
AU - Masao NAKAI
AU - Tasuku TAKAGI
PY - 1988
DO -
JO - IEICE TRANSACTIONS on transactions
SN -
VL - E71-E
IS - 4
JA - IEICE TRANSACTIONS on transactions
Y1 - April 1988
AB - The accumulated metallic phase arc duration in Ag electrical contacts was log-proportional to the amount of electrode mass change, and the relationship was irrespective of the air pressure condition. It can be considered that the electrode mass change closely depends on the metallic phase arc.
ER -