1-3hit |
Umut YUNUS Hai LIN Katsumi YAMASHITA
Due to the importance of maintaining the orthogonality among subcarriers, the estimation of carrier frequency offset (CFO) is a crucial issue in orthogonal frequency division multiplexing (OFDM) systems. The CFO estimation becomes complicated in OFDM direct-conversion receivers (DCRs), where additional analog impairments such as I/Q imbalance and time-varying DC offset (TV-DCO) exist. In this paper, we propose a novel joint estimation method for CFO and I/Q imbalance in the presence of TV-DCO. By using the linear property of the TV-DCO and employing a periodic pilot sequence, the desired estimates can be obtained in closed-form. Simulation results confirm the validity of the proposed method.
Umut YUNUS Hai LIN Katsumi YAMASHITA
In OFDM systems, the estimation/correction of carrier frequency offset (CFO) is crucial to maintain orthogonality among subcarriers. However, the CFO estimation suffers from DC offset (DCO) generated in low-cost direct-conversion receivers (DCRs). More seriously, in practice, DCO is time-varying due to the automatic gain control. In this paper, a novel CFO estimator in the presence of time-varying DCO is proposed. It is shown the residual DCO after high-pass filtering varies in a linear fashion. Based on this observation and the periodicity of the training sequence, we derive a CFO estimator independent of DCO. Also, the residual DCO can be estimated, using the obtained CFO. The validity of the proposed estimation method is demonstrated by simulations.
Umut YUNUS Masaru TSUNASAKI Yiwei HE Masanobu Kominami Katsumi YAMASHITA
Gas or water leaks in pipes that are buried under ground or that are situated in the walls of buildings may occur due to aging or unpredictable accidents, such as earthquakes. Therefore, the detection of leaks in pipes is an important task and has been investigated extensively. In the present paper, we propose a novel leak detection method by means of acoustic wave. We inject an acoustic chirp signal into a target pipeline and then estimate the leak location from the delay time of the compressed pulse by passing the reflected signal through a correlator. In order to distinguish a leak reflection in a complicated pipeline arrangement, the reflection characteristics of leaks are carefully discussed by numerical simulations and experiments. There is a remarkable difference in the reflection characteristics between the leak and other types of discontinuity, and the property can be utilized to distinguish the leak reflection. The experimental results show that, even in a complicated pipe arrangement including bends and branches, the proposed approach can successfully implement the leak detection. Furthermore, the proposed approach has low cost and is easy to implement because only a personal computer and some commonly equipment are required.