This paper proposes a pipeline analog-to-digital converter (ADC) with non-binary encoding technique based on β-expansion. By using multiply-by-β switched-capacitor (SC) multiplying digital-to-analog converter (MDAC) circuit, our proposed ADC is composed by radix-β (1 < β < 2) 1 bit pipeline stages instead of using the conventional radix-2 1.5 bit/1 bit pipeline stages to realize non-binary analog-to-digital conversion. Also with proposed β-value estimation algorithm, there is not any digital calibration technique is required in proposed pipeline ADC. The redundancy of non-binary ADC tolerates not only the non-ideality of comparator, but also the mismatch of capacitances and the gain error of operational amplifier (op-amp) in MDAC. As a result, the power hungry high gain and wide bandwidth op-amps are not necessary for high resolution ADC, so that the reliability-enhanced pipeline ADC with simple amplifiers can operate faster and with lower power. We analyse the β-expansion of AD conversion and modify the β-encoding technique for pipeline ADC. In our knowledge, this is the first proposal architecture for non-binary pipeline ADC. The reliability of the proposed ADC architecture and β-encoding technique are verified by MATLAB simulations.
The copyright of the original papers published on this site belongs to IEICE. Unauthorized use of the original or translated papers is prohibited. See IEICE Provisions on Copyright for details.
Copy
Hao SAN, Tomonari KATO, Tsubasa MARUYAMA, Kazuyuki AIHARA, Masao HOTTA, "Non-binary Pipeline Analog-to-Digital Converter Based on β-Expansion" in IEICE TRANSACTIONS on Fundamentals,
vol. E96-A, no. 2, pp. 415-421, February 2013, doi: 10.1587/transfun.E96.A.415.
Abstract: This paper proposes a pipeline analog-to-digital converter (ADC) with non-binary encoding technique based on β-expansion. By using multiply-by-β switched-capacitor (SC) multiplying digital-to-analog converter (MDAC) circuit, our proposed ADC is composed by radix-β (1 < β < 2) 1 bit pipeline stages instead of using the conventional radix-2 1.5 bit/1 bit pipeline stages to realize non-binary analog-to-digital conversion. Also with proposed β-value estimation algorithm, there is not any digital calibration technique is required in proposed pipeline ADC. The redundancy of non-binary ADC tolerates not only the non-ideality of comparator, but also the mismatch of capacitances and the gain error of operational amplifier (op-amp) in MDAC. As a result, the power hungry high gain and wide bandwidth op-amps are not necessary for high resolution ADC, so that the reliability-enhanced pipeline ADC with simple amplifiers can operate faster and with lower power. We analyse the β-expansion of AD conversion and modify the β-encoding technique for pipeline ADC. In our knowledge, this is the first proposal architecture for non-binary pipeline ADC. The reliability of the proposed ADC architecture and β-encoding technique are verified by MATLAB simulations.
URL: https://globals.ieice.org/en_transactions/fundamentals/10.1587/transfun.E96.A.415/_p
Copy
@ARTICLE{e96-a_2_415,
author={Hao SAN, Tomonari KATO, Tsubasa MARUYAMA, Kazuyuki AIHARA, Masao HOTTA, },
journal={IEICE TRANSACTIONS on Fundamentals},
title={Non-binary Pipeline Analog-to-Digital Converter Based on β-Expansion},
year={2013},
volume={E96-A},
number={2},
pages={415-421},
abstract={This paper proposes a pipeline analog-to-digital converter (ADC) with non-binary encoding technique based on β-expansion. By using multiply-by-β switched-capacitor (SC) multiplying digital-to-analog converter (MDAC) circuit, our proposed ADC is composed by radix-β (1 < β < 2) 1 bit pipeline stages instead of using the conventional radix-2 1.5 bit/1 bit pipeline stages to realize non-binary analog-to-digital conversion. Also with proposed β-value estimation algorithm, there is not any digital calibration technique is required in proposed pipeline ADC. The redundancy of non-binary ADC tolerates not only the non-ideality of comparator, but also the mismatch of capacitances and the gain error of operational amplifier (op-amp) in MDAC. As a result, the power hungry high gain and wide bandwidth op-amps are not necessary for high resolution ADC, so that the reliability-enhanced pipeline ADC with simple amplifiers can operate faster and with lower power. We analyse the β-expansion of AD conversion and modify the β-encoding technique for pipeline ADC. In our knowledge, this is the first proposal architecture for non-binary pipeline ADC. The reliability of the proposed ADC architecture and β-encoding technique are verified by MATLAB simulations.},
keywords={},
doi={10.1587/transfun.E96.A.415},
ISSN={1745-1337},
month={February},}
Copy
TY - JOUR
TI - Non-binary Pipeline Analog-to-Digital Converter Based on β-Expansion
T2 - IEICE TRANSACTIONS on Fundamentals
SP - 415
EP - 421
AU - Hao SAN
AU - Tomonari KATO
AU - Tsubasa MARUYAMA
AU - Kazuyuki AIHARA
AU - Masao HOTTA
PY - 2013
DO - 10.1587/transfun.E96.A.415
JO - IEICE TRANSACTIONS on Fundamentals
SN - 1745-1337
VL - E96-A
IS - 2
JA - IEICE TRANSACTIONS on Fundamentals
Y1 - February 2013
AB - This paper proposes a pipeline analog-to-digital converter (ADC) with non-binary encoding technique based on β-expansion. By using multiply-by-β switched-capacitor (SC) multiplying digital-to-analog converter (MDAC) circuit, our proposed ADC is composed by radix-β (1 < β < 2) 1 bit pipeline stages instead of using the conventional radix-2 1.5 bit/1 bit pipeline stages to realize non-binary analog-to-digital conversion. Also with proposed β-value estimation algorithm, there is not any digital calibration technique is required in proposed pipeline ADC. The redundancy of non-binary ADC tolerates not only the non-ideality of comparator, but also the mismatch of capacitances and the gain error of operational amplifier (op-amp) in MDAC. As a result, the power hungry high gain and wide bandwidth op-amps are not necessary for high resolution ADC, so that the reliability-enhanced pipeline ADC with simple amplifiers can operate faster and with lower power. We analyse the β-expansion of AD conversion and modify the β-encoding technique for pipeline ADC. In our knowledge, this is the first proposal architecture for non-binary pipeline ADC. The reliability of the proposed ADC architecture and β-encoding technique are verified by MATLAB simulations.
ER -